Brunata webmon
Brunata webmon










brunata webmon
  1. #Brunata webmon registration
  2. #Brunata webmon iso

channel n/total consumption (for id no., see item 5.0) The display can show up to two decimals, but the comma may be difficult to see. channel 2/total consumption channel n/id no. channel 1/total consumption channel 2/id no. the flat has a hot water meter (reed), an electricity meter (S01) and a cold water meter (reed), they must be connected as follows in a 1/3 FS: Channel Input Meter type 1 S Reed 80 3 Reed 80 4 Reed Available If it has a gas meter (reed), a heat cost allocator (S01) and an electricity meter (S01), they must be connected to the 3/1 Signal + as follows: Channel Input Meter type 1 S S Reed 95 4 Reed Available NB! Note the number of S01 channels used.Ħ Installation Guide Pages 6/ Display The Signal + display shows data for the input channels used in the following cycle: channel 1/id no. When transferring data from hand terminal to WebBill, the basic physical units are always used provided the relevant input channel is correctly programmed (see item 4.0).ĥ Installation Guide Pages 5/ Prioritisation of meters When meters are allocated to the Signal + channels, the meters must be prioritised in such a way that S01 inputs come before reed inputs: Priority Meter Meter type 1 63 Energy meter, energy 2 80 Energy meter m³ 3 90 Electricity meter 4 95 Gas meter 5 85 Hour counter 6 80 M³ meter cold 7 80 M³ meter warm 8 Available Available If e.g. The Signal + type numbers combine application and meter type in one designation.

#Brunata webmon registration

Type Possible registration units Basic physical unit 80 Cold water meter Litres, m 3 Litre 80 Hot water meter Litres, m 3 Litre 85 Hour counter Hours Hour 90 Electricity meter Wh, kwh, MWh, Wh GWh 95 Gas meter M 3 M 3 63 Energy meter/energy Wh, kwh, MWh, GWh Wh 80 Energy meter/flow MJ, GJ Litres, m 3 Litre Note that these type numbers generally correspond to the numbers used in WebBill. Currently, the following meter type numbers are relevant Signal + : Meter type no. As a given channel, as mentioned above, is hard coded for either reed or S01, it is necessary to know the meters output type before ordering Signal +. Version2 Channel 1 Channel 2 Channel 3 With transmitter 0/ A Reed Reed Reed 1/ A S01 Reed Reed 2/ A S01 S01 ReedĤ Installation Guide Pages 4/14 For the given task, the suitable combination of reed/s01 inputs should be chosen.

brunata webmon

4 channels are available, but 3 optional channels can be active at the same time. The models are designated x/y, where x indicates the number of S01 inputs and y the number of reed inputs. Signal + is available in five versions with different combinations of channels with S01 and reed inputs. The two S01 inputs will be on channel 1 and 2.

brunata webmon

Thus S01 always has the lowest channel numbers (S01 before reed). S01 inputs are always prioritised above reed inputs. 1.2 Meter types and choice of Signal + model As it is presumed that the intention is to count pulses from both energy and flow, a Signal + with min. two meters can be connected to the same Signal + even though they belong to different flats. ( flat ) for accounts purposes, irrespective of their physical location, i.e. Alternatively, they will be located under the same Brunata no. If Signal + output data are required for WebBill, the meters connected to Signal + must be located in the same user unit. The meters are connected to individual input channels on Signal + which can be supplied with or without transmitter. The meters do not need to be the same type (see item 1.2).

#Brunata webmon iso

Our quality system meets DS/EN ISO 9001 and Read more at or contact us atĢ Installation Guide Pages 2/14 Table of contents 1.0 Introduction General description Meter types and choice of Signal + model Prioritisation of meters Display Installation of Signal + and casing Materials Tools Calculation of set-up values for the individual channels Entry in spreadsheet Adjustment of output data Programming of pulse collector Entering set-up values via hand terminal Further programming and test of pulse collector with transmitter Registration of data from pulse collectors Supplementary information about the pulse collector Revision log.14ģ Installation Guide Pages 3/ Introduction 1.1 General description Brunata Futura Signal + (Signal + ), which is built into a Signal + cabinet, is used to collect measurement data from up to four pulse-providing meters. We have more than 90 years of experience within developing and producing heat cost allocators, heating accounts and meter service. 1 Brunata Futura Signal + Installation Guide Edition 2.0 UK-QB / Brunata is a 100% Danish owned company.